Brand Name : Supmeter
Model Number : BST106-M10[FB]
Certification : CE
Place of Origin : China
MOQ : 1pcs
Price : Negotiation
Payment Terms : T/T, Western Union
Supply Ability : 10000pcs per month
Delivery Time : 3-10 working days
Packaging Details : 1pcs/box
Power Supply : DC24V
Max. Connect : 16Loadcells[350Ω]
Input : 7DIs
Output : 18DOs
COM@COM1 : RS232
COM2 : RS485
HMI Weighing Controller For Ration Batching Scale with 4-material&2-speed Feeding
Main Features:
Technical Specification:
| Power Supply | DC24V±20%,Max.10w. | 
| Display | HMI | 
| Sampling Frequency | 800Hz | 
| A/D Convert | 24-bit | 
| LAN | Optional Ethernet | 
| USB1 | Connect mouse, software download, data backup | 
| Max. Connection number of Loadcell |  			 16Loadcells (350Ω)  |  		
| DI | 7 Normally Open Switch Inputs | 
| DO | 18 Normally Open Transistor Switch Outputs | 
| AO | 4Analog Signal Output: 4~20mA. | 
| Operating Temperature | -25℃~+45℃ | 
| Verification Accuracy | 0.02% | 
| Batching Accuracy | 0.2%~0.5% | 
Main Operation Interface for APP1 Single-scale Mode




| Name | Operation | State Indicator | Authorization | 
| 【Auto】 | Auto / Manual [Emergency Stop] switch. |  			 Green: Auto state. Grey: Manual state.  |  			All Users | 
| 【Start】 | Start. |  			 Green: Running state. Grey: Stop state.  |  		|
| 【Re-run】 | Clear Alarm & Recover Running. | ||
| 【Last】 |  			 Last Batch [Normal Stop]. Stop after the present batch finished.  |  			Flashing Red. | |
| 【Pause】 | Pause. | ||
| 【E-stop】 | Emergency Stop. | ||
| 【Alarm】 |  			 Alarm Query / Clear Alarm. ‘Auto/Pause’ state: Recover Running after clearing alarm.  |  			Red: Alarm state. | |
| 【Mat.】 |  			 Material Selection for Auto-Batching. Mixer in Weighing Hopper Running Selection While High-speed Feeding [Only for Single-scale Mode].  |  			 			 Green/Blue: Selected. Grey: Unselected.  |  		|
| 【Print】 |  			 Report Print: 
  |  			||
| 【Lock】 |  			 Screen-locking: Locking/unlocking the operating buttons of main display interface. Auto Screen-locking: Refer to parameter [901].  |  			 			 Flashing Red: Locked. Grey: Unlocked.  |  		|
| 【Menu】 | Enter Main Menu. | ||
| 【User】 | User Login. Display: Operator / Engineer / Admin. | ||
| 【Zero】 | Zero Fine Adjustment [No Power-down Protection]. | Flashing green. | |
| 【High】 | Manual Start/Stop Mn High-speed Feeding. | Green: Working state. | |
| 【Low】 | Manual Start/Stop Mn Low-speed Feeding. | ||
| 【Dump】 | Manual Start/Stop Dumping. | ||
| 【MixbinDump】 | Manual Start/Stop Mixing Bin’s Dumping. | ||
| 【Mn】 | Material Selection for Manual Operation. | ||
| 【Clear】 | Clear Screen: Clear the display values of Feeding Weight, Totalized Weight and Batch Count’. |  			 Engineer Administrator  |  		
Data Display & Quick Setting
| Name | Description | Authorization | 
| Biggest Digits | Real-time Weight / Material Mn’s Feeding Weight [Weight Unit]. | |
| [GROSS] | Gross Weight. | |
| [HI] | Gross Weight Upper Limit Alarm. | |
| [OL] | Overload Alarm. | |
| [CYCLES] | Batch Count. | |
| [▲]/HI | Positive Deviation Alarm. | |
| [▼]/LO | Negative Deviation Alarm. | |
| [TOTAL] | Total Totalized Weight. | |
| [RUN] | Auto Running state. | |
| [PAUSE] | Pause state. | |
| [ZERO] | Gross Weight ≤ Non-load Zero Range. | |
| [STAB] | Weight is stable. | |
| [FED] | Material Mn Feeding Ended. | |
| [AU_FALL] | ‘Fall Value Auto Correction’ Permission. | |
| [ALL_FED] | All Materials Feeding Ended. | |
| [BAT_CON] | ‘Target Batch Control’ is allowed. Refer to parameter [301] ‘ Target Batch Control’ and [203] ‘ Target Batch’. | |
| [BAT_FIN] | Target Batch Finished. | |
| [MIX]/[MIXING] | The mixer is running. | |
| [BELT] | The mixing conveyor is running. | |
| [RECIPE] | ‘Working Recipe’ Setting. | All Users | 
| [Mn TARGET] | Mn Target Value. | |
| [Mn FINAL] | Mn Final Feeding Weight. | |
| [SUM TARGET] | The sum of the Target Values of all the materials selected for batching. | |
| [SUM FINAL] | The sum of the Final Feeding Weight of all the materials selected for batching. | |
|  			 [CYCLES TARGET ] [BAT. COUNT]  |  			Target Batch Count. | |
| [CYCLES FINAL] | Batch Count. | |
| [Time] | Date&Time. | |
HMI TFT-Touch Raiton Filling Controller For Filling Liquid, Gas & Powder Materials

Outline Size

Installation Mode

Terminal Diagram


| 
                                             | 
                